Description
- Product features :
- Agm batteries are dry batteries. And it is safe to use. Batteries convert electrical energy into chemical energy. The internal structure of
- these batteries is different from flooded batteries. It stores itself by charging method. They have lower electrical resistance. There is
- also lower acid stratification compared to flooded batteries. It has a high gas efficiency rate. And it has a lower acidity than others.
- Another feature of Agm batteries is their high power density. Its use is also more flexible. It is long lasting. It is used in many areas.
- It can be easily used especially in uninterruptible power supplies and telecommunication systems. These batteries do not leak acid. It is
- also safe because it has almost no gas emissions.
- Technological Features:
- This can be said for Agm batteries, especially VRLA batteries whose electrolyte is impregnated with separators. It is used in many places
- and is generally used in vehicles. Many things in the vehicle function thanks to the battery. And it is a very cheap method of providing
- uninterrupted energy. Agm batteries can be used especially in vehicles. These batteries are preferred because they are both easy to use and
- cheaper. They are placed inside uninterruptible power supplies. In some cases, when the efficiency of the UPS source increases and the
- battery grows, the battery is placed outside in a separate place and connected to the UPS devices. Battery life is generally 5 years. The
- important thing here is how much heat it is exposed to.
- Scope of application :
- Car
- Truck
- Tractor
- Caravan
- Ambulance
- Boat
- For Starting Purposes in Generators
Part Number: | FZA 2.2-12 |
Length: | 70 ±2 mm (2.76 inches) |
Width: | 48 ±2 mm (1.89 inches) |
Container Height: | 98 ±2 mm (3.86 inches) |
Total Height (with terminal): | 104 ±2 mm (4.09 inches) |
Approx Weight: | Approx 0.80 kg (1.76lbs) |
Nominal Voltage | 12V | |
Nominal Capacity (20HR) | 2.2 AH | |
Terminal Type | Standard Terminal | F1 |
Optional Terminal | - | |
Container Material | Standard Option | ABS |
Flame Retardant Option (FR) | UL94VO | |
Rated Capacity | 2 20 AH/0 110A | (20hr,1 80V/cell 25’0 77* F) |
2.05 AH/0.205A | (10hr.1.80V/cell. 25’0 7FF) | |
1 85AH/0.37A | (5hr,1 75V/ceH, 25’0 77‘F) | |
1 OQAH^SBA | (3hr.1 75V/cell.25cC/77"F) | |
1.38 AH/1 38A | (1hr,1 60V/cell, 25'0 778F) | |
Max Discharge Current | 33A (5s) | |
Internal Resistance | Approx 100m0 | |
Discharge Characteristics | Operating Temp. Range | Diecharge: -15 ~ 50‘C |
Charge: 0 - 40°C | ||
Storage: -15 - 40'C | ||
Nominal Operating Temp. Range | 25+3°C (77+5°F ) | |
Cycle Uoe | Inital Charging Current less than 0.66 A. Voltage 14 4V - 15 OV at 25’C (77’F) Temp Coefficient -30mVfC | |
Standby Use | No limit on Initial Charging Current Voltage 13.5V - 13.8V at 25’C (77°F) Temp Coefficient -20mV/‘C 40”C (104MF) 103% 25’C (77’F) 100% 0°C (32'F) 86% | |
Capacity affect by Temperature | 40‘C 103% | |
25"C 100% | ||
0'C 86% | ||
Design Floating Life at 20°C | 5 Years |