Description
- Product features :
- Agm batteries are dry batteries. And it is safe to use. Batteries convert electrical energy into chemical energy. The internal structure of
- these batteries is different from flooded batteries. It stores itself by charging method. They have lower electrical resistance. There is
- also lower acid stratification compared to flooded batteries. It has a high gas efficiency rate. And it has a lower acidity than others.
- Another feature of Agm batteries is their high power density. Its use is also more flexible. It is long lasting. It is used in many areas.
- It can be easily used especially in uninterruptible power supplies and telecommunication systems. These batteries do not leak acid. It is
- also safe because it has almost no gas emissions.
- Technological Features:
- This can be said for Agm batteries, especially VRLA batteries whose electrolyte is impregnated with separators. It is used in many places
- and is generally used in vehicles. Many things in the vehicle function thanks to the battery. And it is a very cheap method of providing
- uninterrupted energy. Agm batteries can be used especially in vehicles. These batteries are preferred because they are both easy to use and
- cheaper. They are placed inside uninterruptible power supplies. In some cases, when the efficiency of the UPS source increases and the
- battery grows, the battery is placed outside in a separate place and connected to the UPS devices. Battery life is generally 5 years. The
- important thing here is how much heat it is exposed to.
- Scope of application :
- Car
- Truck
- Tractor
- Caravan
- Ambulance
- Boat
- For Starting Purposes in Generators
Part Number: | FZA 4.5-12 |
Length: | 90 ± 2 mm (3.54 inches) |
Width: | 70 ± 2 mm (2.76 inches) |
Container Height: | 101 ± 2 mm (3.98 inches) |
Total Height (with terminal): | 107 ± 2 mm (4.21 inches) |
Approx Weight: | Approx 1.45kg (2.98lbs) |
Nominal Voltage | 12V | |
Nominal Capacity (20HR) | 4.5AH | |
Terminal Type | Standard Terminal | Fl |
Optional Terminal | F2 | |
Container Material | Standard Option | ABS |
Flame Retardant Option (FR) | UL94VO | |
Rated Capacity | 4 50AH/0 225A | (2Ohr, 1 SOV/cell, 25’C / 77*F) |
4 19AH/0 419A | (lOhr, 1.80V/cell.258C/77'F) | |
3.85 AH/O.77A | (5hr, 1 75V/cell, 25*C / 77*F) | |
3.45AH/1.15A | (3hr. 1.75V/cell. 25'C/77*F) | |
2.65AH/2 65A | (Ihr. 1 60V/cell, 25*C / 77*F) | |
Max Discharge Current | 40A (5s) | |
Internal Resistance | Approx 40 mQ | |
Discharge Characteristics | Operating Temp. Range | Diecharge: -15 ~ 50‘C |
Charge: 0 - 40°C | ||
Storage: -15 - 40'C | ||
Nominal Operating Temp. Range | 25+3°C (77+5°F ) | |
Cycle Uoe | Initial Chaigog Current less than 1 35A.Voltage 14.4V * 15.0V at 25‘C (77’F)Temp Coefficient -30mVrc | |
Standby Use | No limit on Initial Charging Current Voltage 13.5V - 13.8V at 25°C (77SF) Temp. Coefficient -20mV/°C | |
Capacity affect by Temperature | 40‘C 103% | |
25"C 100% | ||
0'C 86% | ||
Design Floating Life at 20°C | 5 Years |
Reviews
Be the first to review this item
There are no reviews yet