Description
- Product features :
- Agm batteries are dry batteries. And it is safe to use. Batteries convert electrical energy into chemical energy. The internal structure of
- these batteries is different from flooded batteries. It stores itself by charging method. They have lower electrical resistance. There is
- also lower acid stratification compared to flooded batteries. It has a high gas efficiency rate. And it has a lower acidity than others.
- Another feature of Agm batteries is their high power density. Its use is also more flexible. It is long lasting. It is used in many areas.
- It can be easily used especially in uninterruptible power supplies and telecommunication systems. These batteries do not leak acid. It is
- also safe because it has almost no gas emissions.
- Technological Features:
- This can be said for Agm batteries, especially VRLA batteries whose electrolyte is impregnated with separators. It is used in many places
- and is generally used in vehicles. Many things in the vehicle function thanks to the battery. And it is a very cheap method of providing
- uninterrupted energy. Agm batteries can be used especially in vehicles. These batteries are preferred because they are both easy to use and
- cheaper. They are placed inside uninterruptible power supplies. In some cases, when the efficiency of the UPS source increases and the
- battery grows, the battery is placed outside in a separate place and connected to the UPS devices. Battery life is generally 5 years. The
- important thing here is how much heat it is exposed to.
- Scope of application :
- Car
- Truck
- Tractor
- Caravan
- Ambulance
- Boat
- For Starting Purposes in Generators
Part Number: | FZA 1.2-4 |
Length: | 35 ± 2 mm (1.38 inches) |
Width: | 22 ± 2 mm (0.87 inches) |
Container Height: | 92 ± 2 mm (3.62 inches) |
Total Height (With terminal): | 100 ± 2 mm (3.94 inches) |
Approx Weight: | Approx 0.15kg (0.33lbs) |
Normal Voltage | 4V | |
Normal Capacity (20HR) | 1.2AH | |
Terminal Type | Standard Terminal | / |
Optional Terminal | - | |
Container Material | Standard Option | ABS |
Flame Retardant Option (FR ) | UL94 :VO | |
Rated Capacity | 1.20AH /0.600A | (20hr,1.80V/cell ,25°C /77°F ) |
1.12AH /0.112A | (10hr,1.80V/cell ,25°C /77°F ) | |
1.02AH /0.204A | (5hr,1.75V/cell ,25°C /77°F ) | |
0.918AH /0.306A | (3hr,1.75V/cell ,25°C /77°F ) | |
0.754AH /0.754A | (1hr,1.60V/cell ,25°C /77°F ) | |
Max Discharge Current | 18A(5s) | |
Internal Resistance | Approx 60m | |
Discharge Characteristics | Operating Temp .Range | Discharge :-15-50°C (5-122°F ) |
Charge :0-40°C (5-104°F ) | ||
Storage :-15-40°C (5-104°F ) | ||
Nominal Operating Temp .Range | 25+3°C (77+5°F ) | |
Cycle Use | Initial Charging Current less than 0.36A.Voltage 4.8V-5.0Vat 25°C (77°F )Temp .Coefficient -10mV/°C | |
Standby Use | No limit on Initial Charging Current Voltage 4.5V-4.6Vat 25°C (77°F )Temp .Coefficient -6mV/*C | |
Capacity affected by Temperature | 40°C (104°F )103% | |
25°C (77°F )100% | ||
0°C (32°F )86% | ||
Design Floating Life at 20°C | 5 Years |
Reviews
Be the first to review this item
There are no reviews yet