Description
- Product features :
- Agm batteries are dry batteries. And it is safe to use. Batteries convert electrical energy into chemical energy. The internal structure of
- these batteries is different from flooded batteries. It stores itself by charging method. They have lower electrical resistance. There is
- also lower acid stratification compared to flooded batteries. It has a high gas efficiency rate. And it has a lower acidity than others.
- Another feature of Agm batteries is their high power density. Its use is also more flexible. It is long lasting. It is used in many areas.
- It can be easily used especially in uninterruptible power supplies and telecommunication systems. These batteries do not leak acid. It is
- also safe because it has almost no gas emissions.
- Technological Features:
- This can be said for Agm batteries, especially VRLA batteries whose electrolyte is impregnated with separators. It is used in many places
- and is generally used in vehicles. Many things in the vehicle function thanks to the battery. And it is a very cheap method of providing
- uninterrupted energy. Agm batteries can be used especially in vehicles. These batteries are preferred because they are both easy to use and
- cheaper. They are placed inside uninterruptible power supplies. In some cases, when the efficiency of the UPS source increases and the
- battery grows, the battery is placed outside in a separate place and connected to the UPS devices. Battery life is generally 5 years. The
- important thing here is how much heat it is exposed to.
- Scope of application :
- Car
- Truck
- Tractor
- Caravan
- Ambulance
- Boat
- For Starting Purposes in Generators
Part Number FZA4-4 Length 52.5 ± 2 mm Width 48 ± 2 mm Container Height 94 ± 2 mm Total Height (with terminal) 100 ± 2 mm Approx Weight 0.60 kg Nominal Voltage 4V Nominal Capacity (20HR) 4 AH Terminal TypeStandard Terminal F1 Optional Terminal F2 Container MaterialStandard Option ABS Flame Retardant Option (FR) UL94A/O Rated Capacity2Ohr. 1.80V/CCIJ, 25?C 4 50 AH/0.225A 10hr, 1.80V/cell. 25CC 4.19 AH/0.419A 5hr, 1.75V/cell, 25’C 3 85 AH/0.77A 1hr, 1.60V/cell, 25°C 2 65 AH/2.65A Max Discharge Current 67.5A (5s) Internal Resistance 1 Discharge CharacteristicsOperating Temp. RangeDiecharge: -15 ~ 50‘C Charge: 0 - 40°C Storage: -15 - 40'C Nominal Operating Temp. Range 25 ± 3‘C Cycle Uoe Inilal Charging Current less than 1 35A.Voltage 4.8V - 5.0V Temp. Coefficient -10mVCC Standby Use No limit on Initial Charging Current Voltage 4.5V ~ 4.6V Temp. Coefficient -6mV/aC Capacity affect by Temperature40‘C 103% 25"C 100% 0'C 86% Design Floating Life at 20°C 5 Years