Description
- Product features :
- Agm batteries are dry batteries. And it is safe to use. Batteries convert electrical energy into chemical energy. The internal structure of
- these batteries is different from flooded batteries. It stores itself by charging method. They have lower electrical resistance. There is
- also lower acid stratification compared to flooded batteries. It has a high gas efficiency rate. And it has a lower acidity than others.
- Another feature of Agm batteries is their high power density. Its use is also more flexible. It is long lasting. It is used in many areas.
- It can be easily used especially in uninterruptible power supplies and telecommunication systems. These batteries do not leak acid. It is
- also safe because it has almost no gas emissions.
- Technological Features:
- This can be said for Agm batteries, especially VRLA batteries whose electrolyte is impregnated with separators. It is used in many places
- and is generally used in vehicles. Many things in the vehicle function thanks to the battery. And it is a very cheap method of providing
- uninterrupted energy. Agm batteries can be used especially in vehicles. These batteries are preferred because they are both easy to use and
- cheaper. They are placed inside uninterruptible power supplies. In some cases, when the efficiency of the UPS source increases and the
- battery grows, the battery is placed outside in a separate place and connected to the UPS devices. Battery life is generally 5 years. The
- important thing here is how much heat it is exposed to.
- Scope of application :
- Car
- Truck
- Tractor
- Caravan
- Ambulance
- Boat
- For Starting Purposes in Generators
Part Number: | FZA1.3-6 |
Length: | 97 ± 2 mm (3.82 inches) |
Width: | 24 ± 2 mm (0.94 inches) |
Container Height | 51.5 ± 2 mm (2.03 inches) |
Total Height (with terminal): | 57.5 ± 2 mm (2.26 inches) |
Approx Weight: | Approx 0.29kg (0.639lbs) |
Nominal Voltage | 6V | |
Nominal Capacity (20HR) | 1.3 AH | |
Terminal Type | Standard Terminal | F1 |
Optional Terminal | - | |
Container Material | Standard Option | ABS |
Flame Retardant Option (FR) | UL94VO | |
Rated Capacity | 1.3 AH/0.060A | 2Ohr. 1.80V/CCIJ, 25?C |
1.20 AH/0.112A | 10hr, 1.80V/cell. 25CC | |
1.02 AH/0.204A | 5hr, 1.75V/cell, 25’C | |
0.918 AH/0.306A | 1hr, 1.60V/cell, 25°C | |
Max Discharge Current | 18 A (5s) | |
Internal Resistance | 1 | |
Discharge Characteristics | Operating Temp. Range | Diecharge: -15 ~ 50‘C |
Charge: 0 - 40°C | ||
Storage: -15 - 40'C | ||
Nominal Operating Temp. Range | 25+3°C (77+5°F ) | |
Cycle Uoe | Inilal Charging Current less than 0.36A.Voltage 7.2V - 7.5V Temp. Coefficient -15mVCC | |
Standby Use | No limit on Initial Charging Current Voltage 6.75V ~ 6.9V Temp. Coefficient -10mV/aC | |
Capacity affect by Temperature | 40‘C 103% | |
25"C 100% | ||
0'C 86% | ||
Design Floating Life at 20°C | 5 Years |