Description
For use as a control and signal cable for comnputer systems and electronic control equipment. Not for external and subterranean use. The copper screen provides resistance to external electrical effects, while the screen wrapping around the PVC cores provides protection. The dual helix structure allows the cable to retain its electrical capacity under intense electrical fields.
Cable structure | |
Conductor | IEC 60228 S 5 TS/DIN EN 60228 CLASS 5 Electrolytic strander copper |
Insulation | DIN VDE 0207 - YI2 PVC |
Stranding | Two Cores are twisted in layers at regular intervals |
Color Code | DIN 47100 |
Seperator | PES BANT |
Screen | Tinned copper braid |
Sheath | DIN VDE 0207 Section 5 RAL 7032 |
Technicial Specifications | |
Conductor Resistance | 0.14 mm² = 148 Ω.Km |
0.22 mm² = 96 Ω.Km | |
0.25 mm² = 79.9 Ω.Km | |
0.34 mm² = 56 Ω.Km | |
0.50 mm² = 39 Ω.Km | |
0.75 mm² = 26 Ω.Km | |
1.00 mm² = 19.5 Ω.Km | |
1.50 mm² = 13.3 Ω.Km | |
2.50 mm² = 7.98 Ω.Km | |
Insulation Resistance | > 200 MΩ / Km |
Operating voltage | 0.14 mm² = 350 V |
≤ 0.22 mm² = 500 V | |
Test Voltage | 0.50 mm² < = 1500 V |
0.50 mm² ≥= 2000 V | |
Effective Capacity | 0.14 mm² = 90 nF/km |
0.22 mm² = 100 nF/km | |
0.25 mm² = 100 nF/km | |
0.34 mm² = 110 nF/km | |
0.50 mm² = 120 nF/km | |
0.75 mm² = 120 nF/km | |
1.00 mm² = 120 nF/km | |
1.50 mm² = 120 nF/km | |
2.50 mm² = 120 nF/km | |
Operating temperature | -30°C ~ +80°C |
Flame Test | IEC 60332-1-2 & EN 50265-2-1 |
min. Bending Radius | Fixed Fixed Laying 6,5 x D |
Movable Flexible 15 x D |
Reviews