Description
These cables are used in tools and machines which are subjected to high temperatures, in place with very high or low temperatures in the aerospace industry, nautical industry, cement, glass and ceramic factories, in the steel and iron industry and home appliance field.
Cable structure | |
Conductor | IEC 60228 Class 1 Electrolytic bare copper |
Insulation | Silicon, TS HD 22.1S4 E12 VDE 0282-1 |
Insulation Color Coding | VDE 0293, TS HD 308 S2 |
Technicial Specifications | |
Conductor Resistance | 0.50 mm² = 39 Ω.Km |
0.75 mm² = 26 Ω.Km | |
1.00 mm² = 19.5 Ω.Km | |
1.50 mm² = 13.3 Ω.Km | |
2.50 mm² = 7.98 Ω. Km | |
4.00 mm² = 4.95 Ω.Km | |
6.00 mm² = 3.30 Ω.Km | |
10.00 mm² = 1.91 Ω.Km | |
16.00 mm² = 0.21 Ω.Km | |
25.00 mm² = 0.780 Ω.Km | |
35.00 mm² = 0.554 Ω.Km | |
50.00 mm² = 0.386 Ω.Km | |
70.00 mm² = 0.272 Ω.Km | |
95.00 mm² = 0.206 Ω.Km | |
120.00 mm² = 0.161 Ω.Km | |
150 .00 mm² = 0.129 Ω.Km | |
185.00 mm² = 0.106 Ω.Km | |
240.00 mm² = 0.0801 Ω.Km | |
Insulation Resistance | > 20 MΩ / Km |
Operating voltage | 0.50 mm² to 1.00 mm² (inclusive) = 300/500 V |
| 1.50 mm² to 240 mm² (inclusive) = 450/750 V |
Insulation Durability | IEC 60331-21 |
Operating temperature | -60 °C ~ +180 °C |
min. Bending Radius | Fixed Fixed Laying 6,5 x D |
Movable Flexible 10 x D | |
Flame Test | IEC 60332-1-2 & TS/DIN EN 50265-2-1 |