Description
- Product features:
- Solar batteries are batteries that contain a jelly-like electrolyte.
- They are maintenance-free batteries that are resistant to harsh environmental conditions, especially temperature and vibration. That's why
- they are especially preferred in the marine industry and solar energy systems. Dry Batteries, known as Maintenance-Free Batteries, and Solar
- Batteries are batteries that fall into this class. It is also called SLA Battery (Sealed Lead Acid).
- VRLA Batteries are used in UPS (Uninterruptible Power Supply) systems, telecommunications, electricity and telephone power plants,
- electricity generation companies, emergency lighting systems and security systems.
- Even if the Solar Battery is not charged immediately, it can be fully recovered from deep discharge. Ideal for daily cyclic use.
- They show excellent performance during long discharges.
- Technological Features:
- Our solar batteries are gel batteries, their most important feature or usage area is that they are used in "deep discharge" applications.
- Gel batteries are called "maintenance-free batteries" because they do not require the addition of pure water during use.
- The most important feature of gel batteries and their difference from dry charged batteries is their deep discharge feature.
- So what is this deep discharge? The deep discharge level of gel batteries is 75% compared to dry or flooded batteries. To put it more
- clearly, when we charge gel batteries after discharge, the charging is completed without any damage to the chemical structure inside them.
- When you do the same thing with dry or flooded batteries, that is, when you charge them after deep discharge, the life of the battery
- shortens with each charge as the chemicals in the battery will be damaged with each charge.
- To summarize; can be said that charging and discharging operations do not affect the battery performance.
- Scope of application :
- Air Traffic Control Center
- Barcode Devices
- Cash Registers
- Electronic Doors
- Computer Aided Automation
- elevator
- Airport Lighting
- Emergency Lighting Systems
- Medical Electronic Devices
- Military Radar System
- Photo Printing Devices
- Electronic Scales
- Communication and Broadcasting Organizations
- Uninterruptible power supply
- Solar Energy Systems
Part Number: | FZA150-12 |
Length: | 485 ±2 mm (13.5 inches) |
Width: | 170 ±2 mm (6.73 inches) |
Container Height: | 240 ± 2 mm (10.79 inches) |
Total Height (with terminal): | 240 ± 2 mm (11.02 inches) |
Nominal Voltage | 12V | |
Nominal Capacity (10HR) | 150AH | |
Terminal Type | Standard Terminal | F11 |
Optional Terminal | - | |
Container Material | Standard Option | ABS |
Flame Retardant Option (FR) | ABS (UL94:VO) | |
Rated Capacity | 156.0 AH/7.80A | (20hr,1.80V/cell, 25°C/77°F) |
150.0 AH/15.0A | (10hr,1.80V/cell, 25°C/77°F) | |
130.5 AH/26.1 A | (5hr,1.75V/cell, 25°C / 77°F) | |
115.2 AH/38.4A | (3hr,1.75V/cell,25°C/77T) | |
Max Discharge Current | 1500A (5s) | |
Internal Resistance | Approx 3.5mQ | |
Discharge Characteristics | Operating Temp. Range | Discharge: -15 - 50°C (5 - 122°F) |
Charge: 0 ~ 40°C (5 ~ 104T) | ||
Storage: -15 - 40°C (5 - 104°F) | ||
Nominal Operating Temp. Range | 25 ± 3°C (77 ± 5°F) | |
Cycle Use | Inital Charging Current less than 45.0A.Voltage 14.4V - 15.0V at 25°C (77°F) Temp. Coefficient -30mV/°C | |
Standby Use | No limit on Initial Charging Current Voltage 13.5V * 13.8V at 25°C (77°F) Temp. Coefficient -20mV/°C | |
Capacity affected by Temperature | 40°C (104°F) 103% | |
25°C (77°F) 100% | ||
0°C (32°F) 86% | ||
Design Floating Life at 20°C | 10 Years |
Reviews
Be the first to review this item
There are no reviews yet