Description
- Product features:
- Solar batteries are batteries that contain a jelly-like electrolyte.
- They are maintenance-free batteries that are resistant to harsh environmental conditions, especially temperature and vibration. That's why
- they are especially preferred in the marine industry and solar energy systems. Dry Batteries, known as Maintenance-Free Batteries, and Solar
- Batteries are batteries that fall into this class. It is also called SLA Battery (Sealed Lead Acid).
- VRLA Batteries are used in UPS (Uninterruptible Power Supply) systems, telecommunications, electricity and telephone power plants,
- electricity generation companies, emergency lighting systems and security systems.
- Even if the Solar Battery is not charged immediately, it can be fully recovered from deep discharge. Ideal for daily cyclic use.
- They show excellent performance during long discharges.
- Technological Features:
- Our solar batteries are gel batteries, their most important feature or usage area is that they are used in "deep discharge" applications.
- Gel batteries are called "maintenance-free batteries" because they do not require the addition of pure water during use.
- The most important feature of gel batteries and their difference from dry charged batteries is their deep discharge feature.
- So what is this deep discharge? The deep discharge level of gel batteries is 75% compared to dry or flooded batteries. To put it more
- clearly, when we charge gel batteries after discharge, the charging is completed without any damage to the chemical structure inside them.
- When you do the same thing with dry or flooded batteries, that is, when you charge them after deep discharge, the life of the battery
- shortens with each charge as the chemicals in the battery will be damaged with each charge.
- To summarize; can be said that charging and discharging operations do not affect the battery performance.
- Scope of application :
- Air Traffic Control Center
- Barcode Devices
- Cash Registers
- Electronic Doors
- Computer Aided Automation
- elevator
- Airport Lighting
- Emergency Lighting Systems
- Medical Electronic Devices
- Military Radar System
- Photo Printing Devices
- Electronic Scales
- Communication and Broadcasting Organizations
- Uninterruptible power supply
- Solar Energy Systems
Part Number : | FZA 65-12 |
Length : | 348 ± 2 mm ( 13.70 inches ) |
Width : | 167 ± 2 mm ( 6.57 inches ) |
Container Height : | 178 ± 2 mm ( 7.01 inches ) |
Total Height ( with terminal ) : | 178 ± 2 mm ( 7.01 inches ) |
Nominal Voltage | 12V | |
Nominal Capacity ( 20HR ) | 65AH | |
Terminal Type | Standard Terminal | F6 |
Optional Terminal | F10 | |
Container Material | Standard Option | ABS |
Flame Retardant Option ( FR ) | ABS ( UL94 : VO ) | |
Rated Capacity | 65.0 AH / 3.40A | ( 20hr , 1.80V / cell , 25 ° C / 77 ° F ) |
62.5.0 AH / 6.50A | ( 10hr , 1.80V / cell , 25 ° C / 77 ° F ) | |
56.0 AH / 11.2A | ( Shr , 1.75V / cell , 25 ° C / 77 ° F ) | |
48.9 AH / 16.3A | ( 3hr , 1.75V / cell , 25 ° C / 77 ° F ) | |
Max Discharge Current | 780A ( 56 ) | |
Internal Resistance | Approx 7.3m | |
Discharge Characteristics | Operating Temp . Range | Discharge : -15-50 ° C ( 5-122 ° F ) |
Charge : 0-40 ° C ( 5 - 104 ° F ) | ||
Storage : -15-40 ° C ( 5 - 104 ° F ) | ||
Nominal Operating Temp . Range | 25 ± 3 ° C ( 77 ± 5 ° F ) | |
Cycle Use | Inital Charging Current less than 19.5A.Voltage 14.4V - 15.0V at 25 ° C ( 77 ° F ) Temp . Coefficient -30mV / " C | |
Standby Use | No limit on Initial Charging Current Voltage 13.5V - 13.8V at 25 ° C ( 77 ° F ) Temp . Coefficient -20mV / " C | |
Capacity affected by Temperature | 40 ° C ( 104 ° F ) 103 % | |
25 ° C ( 77 ° F ) 100 % | ||
0 ° C ( 32 ° F ) 86 % | ||
Design Floating Life at 20 ° C | 10 Years |
Reviews
Be the first to review this item
There are no reviews yet